HP Cluster Platform InfiniBand Interconnect Installation and User's Guide

Technical SpecificationFeature
Power consumption*:Power Rating
ISR 9024S — 51W, max.
ISR 9024S-M — 63W, max.
ISR 9024D — 58W, max.
ISR 9024D-M — 69W, max.
BTU/hour = Watts x 3.413
90 Vac/60 Hz/Max Load = 0.998Power Factor:
120 Vac/60 Hz/Max Load = 0.997
230 Vac/60 Hz/Max Load = 0.973
264 Vac/60 Hz/Max Load = 0.957
120WMaximum Power Draw
82%Power Supply Efficiency
0.737 [mA]Leakage current @ 264V
2 power cords, 2 meter jumper, with a universal plug for PDU (Power Distribution Unit).
Acoustic Data
ISR Noise power is 6.5db.
Physical Characteristics
1.69" (43 mm) x 16.929" (430 mm) x 20.59" (523 mm)Dimensions (H x W x D)
19” (482.6 mm), with optional front or rear rack mountingRack column width
17 lb (7.7 kg), excluding rack mountingWeight
Reliability
over 160,000 hoursInternally managed
over 200,000 hoursExternally managed
Environmental Operating
32°F to 113°F (0°C to 45°C)Temperature
15% to 80%, non-condensingHumidity
0 to 9843 ft (3000m)Altitude
Environmental Storage
–13°F to 185°F (-25°C to +85°C)Temperature
5% to 90% non-condensingHumidity
0 ft to 15,000 ft (4570 m)Altitude
Maximum Ambient Temperature
45°C
Certifications of Compliance
cULus (USA-E17018/CAN-ICES/NMB-003 Class/Classe A)Safety
CE according EN 60950-1 First Ed.
CB according IEC 60950-1 First Ed.
114 ISR 9024 S/D Interconnect Specifications (RoHS Compliant)