Quadrics QsNetII Interconnect

7. To confirm that the upgrade has completed successfully, reconnect to the
interconnect as follows:
cp6000sms# telnet QR0T00
8. The Quadrics Switch Control menu is displayed again, as shown in step 1.
9. Choose option 3 to run the jtest command , as follows
cp6000sms# jtest QR0T00
jtest: initialising module QR0T00
10. Use the info command to verify the firmware revision as follows
jtest> info
Selected boards : 0
Selected elites :01234567
------------|--------------|----------------------------|-----------|
Name | Type | Info | Environ’t |
------------|--------------|----------------------------|-----------|
QR0T00 | QS2_64U64D | Redundant : no | A B |
------------|--------------| Federated : yes | PSU OK OK |
Slot ’C Slot ’C | ClockSource : A | FAN rpm |
0 QM501_CU 40 4 QM502_CU 40| Freq: 656.08 | 1 3690 |
1 QM501_CU 38 5 QM502_CU 35| F’ware Id: 43-4092911 | 2 3700 |
2 QM501_CU 37 6 - | Upgrade 503-upgrade.tar | 3 3720 |
3 QM501_CU 37 7 - | Protocol: static | 4 3668 |
| MAC: 00:40:53:06:f5:73 | 5 3629 |
8 controller card 27 9 - | IP: 172.20.66.9 | 6 3680 |
---------------------------|----------------------------|-----------|
11. Exit the jtest utility as follows:
jtest> quit
12. Repeat the previous steps for each interconnect in the cluster.
11-6 Accessing and Using the Interconnect Control Menu