Quadrics QsNetII Interconnect

"<module>: <swmserver type=""> <ip> <mac> <module type="">..."
When communication is established with a interconnect module, basic
configuration information is logged to syslog.
"<module>: swmserver restarted"
This message indicates that communication with an interconnect module is
established (such as after the swmserver process is restarted).
"<module>: heartbeat"
Every five minutes, each interconnect module sends out this heartbeat
message, indicating that it is functioning.
"<module>: problem: updates have stopped"
This message indicates that swmlogger has received no communication from
an interconnect module for 20 minutes.
"<module>: problem: inconsistent firmware revision"
This message indicates that swmlogger has detected a interconnect module
with an inconsistent firmware revision. It compares firmware revisions to
that of the first module that signs in.
"<module>: problem: power/control problem"
This message indicates that an interconnect module of an unknown type has
tried to establish communication with swmlogger.
"<module>: link B:C:L: <link message="">"
Link messages are identified as board B, chip C, and link L. Common
messages in the log file are:
link in reset
link ok
Theses message occur when the PCI card driver forces the link into reset each
time a node reboots.
"<module>: psu: <psu message="">"
This message indicates the power supply module status, which can be on
or off.
"<module>: fan: <fan message="">"
This message indicates fan speed changes. Only changes of 50 RPM or more
are reported.
"<module>: temp: <temp message="">"
This message indicates module temperature changes. Only changes of 2
degrees Celsius or more are reported.
"<module>: hotplug: <hotplug message="">"
This message indicates hot-pluggable board insertion or removal, such as
board removed from slot slot id or board inserted in slot slot id.
12-16 Maintenance and Diagnostic Procedures