Quadrics QsNetII Interconnect
"<module>: clock: <clock message="">"
This message indicates a change in the interconnect clock signal. A clock
failure means the clock frequency has drifted +/-1.0 MHz from 656 MHz,
while clock ok means the clock frequency has returned to within specification.
12.7.2 Using swmlogger for Production Mode Testing
Use the output from the swmlogger to monitor the system during production
mode, as described by the flowchart in Figure 12-1.
Figure 12-1: Production mode Testing Using swmlogger
End
Start.
Verify that the swmlogger is configured and running.
Is it configured
and running?
No
Yes
Configure the
swmlogger.
Check the log file account where swmlogger is
configured to send alerts and error messages.
Are there any errors?
Are they
critical?
No
No
Yes
Yes
Feel assured that the
machine appears to be
operating correctly.
Continue operation
until the next
scheduled drain
time test.
Schedule
immediate
downtime to
diagnose and repair
the cluster.
HPTC-0025
12.8 Using jtest to Identify Link Errors
You can use the jtest utility with its errors option to detect link errors. The
jtest> errors command shows any errors detected on the interconnect registers
Maintenance and Diagnostic Procedures 12-17