Quadrics QsNetII Interconnect

7.3.1 Installing a QM501 or QM502 Switch Card
Color-coded keys, known as midplane polarizing keys, are fitted to the switch cards
and to the midplane of the interconnect. These keys prevent the switch cards from
being fully inserted in an incorrect slot. Polarizing keys function as follows:
QM501 cards are normally installed in slots 0-3. Some interconnect
configurations contain QM54X midplanes. In these configurations you can
install QM501 switch cards in slot positions 4-7. In this case, midplane
polarizing keys are not fitted.
QM502 switch cards are normally installed in slots 4-7. Some interconnect
configurations contain QM54X midplanes. In these configurations you can
install QM502 switch cards in slot positions 4-7. In this case, midplane
polarizing keys are not fitted
Install the QM501 or QM502 as follows:
1. 1. Unpack the switch cards, and insert them in the vertical slots in the
interconnect enclosure, as shown in Figure 7-5. Start with the lowest
numbered slot (slot 0 or slot 4) and then fill slots progressively to the highest
numbered slot.
Figure 7-5: Inserting a Switch Card
Latches
Switch Card
Screw
PSU A
PSU B
QU
a
D
rics
QsNet"
QsNet"
HPTC-0027
2. Snap the switch card in place by applying force evenly to the two latches.
3. When the switch card is latched down, secure the two latches using the captive
screws.
7.3.2 Installing a QM511C or a QM511L Switch Card
Install QM511C switch cards as follows:
1. Ensure that the midplane is a QM542 and not a QM540.
Installation and Maintenance of the 128-Port Interconnect 7-5