Quadrics QsNetII Interconnect
12. On systems not running HP XC, use the following procedure:
a. Determine whether your system is a full bandwidth or reduced bandwidth
configuration. If the cluster has a reduced bandwidth configuration,
follow the additional test rules defined in Section 12.11.
b. Run the
qsnet2_dmatest on the appropriate nodes, depending on the
cluster bandwidth. Specify the U1, U2, U3, U4, and U5 level arguments as
explained in Section 12.4. Verify that all specified nodes pass on all levels.
13. On systems running HP XC, run the selftest as described in Section 11.4.
After the self test is complete, use the neterror command to check the
database for errors
On systems not running HP XC, perform a generic soak test as described
in Section 12.13.
14. Clusters installed with HP XC are configured during the installation process
to use the swmlogger to record events in a database. For systems not running
HP XC, configure the swmlogger to log events to the syslog utility, as
described in Section 12.7.
9.5 Diagnostic Flowchart
The flowchart shown in Figure 9-1 shows the sequence of steps for performing
diagnostic tests and system verification.