Quadrics QsNetII Interconnect

10.2.2 Controller Card LEDs
The LEDs on the interconnect’s QM503 control card provide the following
diagnostic information:
Label
Color
Interpretation Diagnostic
Pri Clk OK
green
The input from the primary clock is good. This
indicator applies only when the interconnect
is part of a federated configuration.
Error if OFF
Sec Clk OK
green
The input from the secondary clock is good. Error if OFF
B Clock
Active
amber The secondary controller (slot A) clock is inactive. Error if ON
Clk Error red A clock error is detected. Error if ON
Federated
green
This interconnect is part of a federated
configuration.
True if ON
Redundant
green
This interconnect is part of a redundant
configuration.
True if ON
Ctrl Run
green
This controller has booted and has a status of good.
This indicator might take up to five minutes to
illuminate after the controller is rebooted.
Error if OFF
Cntrl Error red The controller in slot A is not operating correctly. Error if OFF
B Cntrl
Active
amber The controller in slot A is not operating correctly,
and its error status LED (red) will be illuminated.
Error if OFF
Fan Fail A red The QM562 module in fan tray A has failed. Error if ON
Fan Fail B red The QM562 module in fan tray B has failed. Error if ON
10.2.3 Power Supply Unit LEDs
The LEDs in the QS5A power supply unit (PSU) provide the following diagnostic
information:
Label Interpretation
Good
Status
Error
Status
AC OK The alternating current (AC) power inlet supply indicator. Green Red
FAULT PSU fault indicator. This might illuminate if the alternating
current (AC) power inlet supply or DC output indicator.
OFF Red
OVER
TEMP
The PSU temperature indicator. This might illuminate if
the PSU runs too hot, perhaps due to a fan problem.
OFF Red
DC OK The DC power output indicator. This might illuminate
if the DC voltage drops below a specified level.
Green Amber
10.2.4 Clock Generator LEDs
The LEDs in the QM580 clock generator provide the following diagnostic
information:
Label Interpretation
Good
Status
Error Status
PWR ON The AC power supply is working (power
is applied to the clock).
Green OFF
CLK In Ok This clock generator is in slave mode and its
input from the master clock is OK.
Green N/A (status
only)
Using Component LEDs 10-5