HP Cluster Platform Server and Workstation Overview

17. Reinstall the access panel, reversing the steps in Section 3.1.2.
18. Replace the server in the rack, reversing the steps in Section 3.1.2.
19. Attach the cable between the card and the switch, and reconnect the AC power cord.
20. Press the Power button on the server. Check that the card is detected. Refer to your software
documentation for further installation instructions.
For more information, refer to the following documents:
PCI Express Riser Board Installation Instructions for HP ProLiant DL100 Series Generation 2
Servers
HP ProLiant 100 Series Servers User Guide
HP ProLiant DL145 Generation 2 Server Maintenance and Service Guide
HP ProLiant DL145 Generation 2 Server Installation Sheet
3.2 HP ProLiant DL145 G3
The HP ProLiant DL145 G3 is supported in HP Cluster Platform solutions. The HP ProLiant
DL145 G3 server supports up to two AMD Opteron processors and can be used as an application
node, utility node, or control node. Table 3-4 lists the features of the HP ProLiant DL145 G3.
Table 3-4 HP ProLiant DL145 G3 Specifications
SpecificationFeature
Supports up to two AMD Opteron 2000 series processorsProcessors
Supports dual-core 2.6 GHz, 1 MB cache processors
Supports DirectConnect Architecture
8 DIMM slots supporting up to 16 GB PC2-5300 DDR2-667 MHz memory with
Advanced ECC
Memory
Supports up to two:Internal Drive Support
– Hot Plug Serial Attached SCSI (SAS) 3.5"/Serial ATA (SATA) hard drives, or;
– Non-Hot Plug Serial ATA (SATA) 3.5" hard drives
Internal storage capacity of up to 1.5 TB (2 x 750 GB hot-pluggable 3.5 inch SATA
hard drives), or 600 GB (2 x 300 GB hot plug 3.5" SAS hard drives)
NC326i PCIe Dual Port Gigabit Server AdapterNetwork Controller
HP Embedded SATA Controller on Non-Hot Plug SATA ModelsStorage Controllers
HP Smart Array E200 Controller with 64 MB cache, optional
– Upgradeable to 128 MB write back cache
HP 8 Internal Port SAS HBA with RAID 0,1 on hot-pluggable SATA/SAS Models
Standard - PCI Express assembly includes:Expansion Slots
– Slot 1: full-length/full-height PCI Express x16
– Slot 2: half-length/low-profile PCI Express x4 (x8 connector)
Optional - PCI-X assembly includes:
– Slot 2: half-length/low-profile PCI-X 133 (note: PCI-X slots are 64 bits; 133 MHz
capable)
Optional - HTX assembly includes: Slot 1: full-length/full-height HTX
IPMI 2.0 supportManagement
HP ProLiant Lights Out 100i Remote Management support
ROM Setup Utility
110 Opteron Processor Servers