HP Cluster Platform Server and Workstation Overview

11. To put the server back into the rack, press the server rail-release latches and slide the server
fully into the rack.
Warning!
To reduce the risk of personal injury, be careful when pressing the server rail-release latches
and sliding the server into the rack. The sliding rails could pinch your fingers.
3.5.5 Replacing a ProLiant DL385 G2 PCI Card
When replacing a PCI adapter card, you need a grounding strap. The adapter card is sensitive
to electrostatic discharge. Take care to avoid mishandling, which could damage the card. Before
beginning installation, and without removing the adapter card from its antistatic bag, inspect
the card for any signs of obvious damage, such as chipped or loose components.
To replace a PCI card in the ProLiant DL385 G2 riser cage, follow these steps:
1. Attach the grounding strap to your wrist or ankle and to a metal part of the chassis.
2. Power off the server.
3. Remove the server from the rack.
4. Remove the access panel from the server, and locate the PCI riser cage (slots 3–5).
5. Disconnect any cables connected to any existing expansion boards.
6. Remove the PCI riser cage, as shown in Figure 3-41.
Figure 3-41 Removing the ProLiant DL385 G2 PCI Riser Cage
1
2
3
7. It might be necessary to remove a slot cover, or move a slot cover to a different slot. Remove
a slot cover in the PCI riser cage, as shown in Figure 3-42.
134 Opteron Processor Servers