HP Cluster Platform Server and Workstation Overview
1. Remove the server from the rack, as described in Section 3.7.2.
2. Locate and remove the Torx T-15 tool that is stored on the back of the server chassis, between
the fans and the PCI slots.
3. Unlock the access panel latch using the Torx T-15 tool, as shown in Figure 3-48, that you
removed from the back of the server.
Figure 3-48 Unlocking the HP ProLiant DL585 Access Panel Latch
hp
3
2
1
DescriptionItem
Access panel Torx T-15 tool1
Access panel latch2
Access panel3
4. Lift up on the latch and remove the access panel.
To replace the access panel, place the panel on top of the server with the latch open. Allow the
panel to extend past the rear of the server approximately 1.25 cm (0.5 in). Push down on the
latch. The access panel slides to a closed position.
To return an HP ProLiant DL585 server into a rack, press the rail-release levers at the front of
both server rails and slide the server into the rack, as shown in Figure 3-49. Secure the server by
tightening the thumbscrews.
Figure 3-49 Sliding an HP ProLiant DL585 into a Rack
HPTC-0224
3.7 HP ProLiant DL585 141