HP Cluster Platform Server and Workstation Overview

18. Attach any cables between the card and the switch, and reconnect the AC power cord.
19. Press the Power button on the server. Check that the card is detected. Refer to your software
documentation for further installation instructions.
3.9 HP ProLiant DL585 G5
The HP ProLiant DL585 G5 server typically functions as a control node, utility node, or compute
(application) node in HP Cluster Platform. When using the ProLiant DL585 G5 as the control
node, a redundant power supply is mandatory. Otherwise, a redundant power supply is optional.
The 4U ProLiant DL585 G5 server can be configured with up to four AMD Opteron quad-core
processors and up to 128 MB of memory.
For the features and specifications of the ProLiant DL585 G5, go to the QuickSpecs on the HP
website:
http://h18004.www1.hp.com/products/quickspecs/13016_na/13016_na.html
The front and rear panel features of the ProLiant DL585 G5 are the same as the ProLiant DL585
G2. See Figure 3-53 (page 145) and Figure 3-54 (page 146).
3.9.1 PCI Slot Assignments
The following table provides the PCI slot assignments for ProLiant DL585 G5 when the server
is used in HP Cluster Platform solutions.
CommentAssignmentSlot
PCI-X, 64-bit/100-MHzPCI-X Interconnect1
PCI-X, 64-bit/100-MHz2
PCI Express x41 Gigabit/second Ethernet NIC3
PCI Express x44
PCI Express x81st 2 Gigabit/second Fibre Channel HBA
(Optional)
5
PCI Express x46
PCI Express x8PCI Express Interconnect7
PCI Express x88
PCI Express x49
For additional information, such as the system board layout and installing PCI cards, see the HP
ProLiant DL585 Generation 5 Server Maintenance and Service Guide:
http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c01384250/c01384250.pdf
152 Opteron Processor Servers