HP Cluster Platform Server and Workstation Overview

DescriptionItem
Multifunction Gigabit Ethernet NIC 112
Multifunction Gigabit Ethernet NIC 213
2.5.3 HP ProLiant DL360 G5 Front Panel LEDs
The HP ProLiant DL360 G5 front panel LEDs are shown in Figure 2-22.
Figure 2-22 ProLiant DL360 G5 Front Panel LEDs
4
65
1 2 3 4
The following table describes the callouts in Figure 2-22.
Table 2-16 ProLiant DL360 G5 Front Panel LEDs
StatusDescriptionItem
Green = System is on.Power On/Standby button and system
power LED
1
Amber = System is shut down, but power is still applied.
Off = Power cord is not attached, power supply failure has
occurred, no power supplies are installed, facility power is
not available, or disconnected power button cable.
Blue = Identification is activated.Unit Identification Button (UID) button2
Flashing blue = System is being remotely managed.
Off = Identification is deactivated.
Green = System health is normal.Internal health LED3
Amber = System health is degraded. To identify the
component in a degraded state, see Section 2.5.5.
Red = System health is critical. To identify the component
in a critical state, see Section 2.5.5.
Off = System health is normal (when in standby mode).
Green = Power supply health is normal.External health LED (power supply)4
Amber = Power redundancy failure occurred.
Off = Power supply health is normal when in standby mode.
Green = Network link exists.NIC 1 link/activity LED5
Flashing green = Network link and activity exist.
Off = No link to network exists.
76 Xeon Processor Servers