Broadcom iSCSI Boot for HP FlexFabric Adapters User Guide
Table Of Contents
- Broadcom iSCSI Boot for HP FlexFabric Adapters User Guide
- Abstract
- Notice
- Contents
- Introduction
- Setup
- iSCSI boot setup
- Configuring the iSCSI target
- Configuring iSCSI boot parameters
- Preparing the iSCSI boot image
- Booting
- Other iSCSI boot considerations
- iSCSI offload in Windows server
- iSCSI boot setup
- Troubleshooting
- Boot fails when switching to Broadcom iSCSI offload
- Broadcom iSCSI Crash Dump utility does not capture a memory dump
- HBA offload miniport BXOIS does not load
- Inbox driver does not update
- Installing Windows on an iSCSI target fails
- IP address conflict
- iSCSI target is not recognized as an installation target
- iSCSI configuration utility does not run
- NDIS miniports with Code 31 yellow-bang after L2 iSCSI boot installation
- System blue screen appears after setting iSCSI boot LUN to 255
- System blue screen occurs when installing through Windows Plug-and-Play
- System blue screen occurs when iSCSI boots Windows 2008 R2
- Frequently asked questions
- Event notifications
- Regulatory compliance notices
- Support and other resources
- Acronyms and abbreviations
- Documentation feedback
- Index
Event notifications 35
Message
Number
Severity Message
51
Error
Target failed to respond in time to a logout request sent in response to an
asynchronous message from the target.
52
Error Initiator service failed to respond in time to a request to configure IPSec
resources for an iSCSI connection.
53
Error Initiator service failed to respond in time to a request to release IPSec resources
allocated for an iSCSI connection.
54
Error Initiator service failed to respond in time to a request to encrypt or decrypt data.
55
Error Initiator failed to allocate resources to send data to target.
56
Error Initiator could not map an user virtual address to kernel virtual address, resulting
in I/O failure.
57
Error Initiator could not allocate required resources for processing a request, resulting
in I/O failure.
58
Error Initiator could not allocate a tag for processing a request, resulting in I/O
failure.
59
Error Target dropped the connection before the initiator could transition to Full
Feature Phase.
60
Error Target sent data in the SCSI Response PDU instead of Data_IN PDU. Only Sense
Data can be sent in SCSI Response.
61
Error Target set DataPduInOrder to NO when the initiator requested YES. Login fails.
62
Error Target set DataSequenceInOrder to NO when the initiator requested YES. Login
fails.
63
Error The target or LUN cannot be reset. Session recovery is attempted.
64
Information An attempt to bootstrap Windows using iSCSI NIC Boot iBF is in progress.
65
Error Booting from iSCSI is in progress, but no NIC could be set in the Paging Path.
66
Error An attempt to disable the Nagle Algorithm for iSCSI connection failed.
67
Information
If digest support is selected for iSCSI Session, processor support for digest
computation is used.
68
Error After receiving an async logout from the target, an attempt to re-login the session
failed. Error status is given in the dump data.
69
Error An attempt to recover an unexpected terminated session failed. Error status is
given in the dump data.
70
Error An error occurred when processing iSCSI login request. The request was not
retried. Error status is given in the dump data.
71
Information Initiator did not start a session recovery upon receiving the request. Dump data
contains the error status.
72
Error Unexpected target portal IP types were found. Dump data contains the expected
IP type.