HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

DescriptionStatusParameter name
Model of the storage systemRequired
model
Specify true to assign volumes for Thin Provisioning Software
to a pool for Thin Provisioning Software.
Specify false to release volumes for Thin Provisioning Software
from a pool for Thin Provisioning Software.
Omit this parameter if you are changing the threshold value.
Optional
(XP24000/XP20000)
assign
Device number(s) of volume(s) for Thin Provisioning Software
Specify this parameter as a decimal number or colon-delimited
hexadecimal number in the format ww:xx:yy, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number.
ww is optional. If ww is omitted, LDKC is assumed to be 0.
Use a comma to delimit multiple values.
Required
devnums
Pool ID of the pool for Thin Provisioning Software
You need specify this parameter only if true is specified for the
assign parameter.
Optional
(XP24000/XP20000)
poolid
Usage rate threshold for the volumes for Thin Provisioning
Software (%)
Specify this parameter when you are assigning volumes for Thin
Provisioning Software to a pool for Thin Provisioning Software,
or when you are changing the threshold value.
Specify a multiple of 5 from 5 to 300.
If this parameter is omitted when true is specified for the assign
parameter, 5 is set.
This parameter must be specified if the assign parameter is
omitted.
Do not specify this parameter when false is specified for the
assign parameter. If the parameter is specified in this condition,
an error will occur.
Optional
(XP24000/XP20000)
threshold
Capacity of the THP volume after expansion (KB)
Specify the capacity of the expanded volume. The maximum value
that can be specified is 64424505600.
Required
(P9500)
capacity
Parameter values to obtain in advance
serialnum and model: Obtain these values from the execution result of the GetStorageArray
command. In the execution result, use the arrayType value or the displayArrayType value to
specify the model parameter, and use the serialNumber value to specify the serialnum parameter.
devnums: Obtain this value from the execution result of the GetStorageArray (subtarget=LDEV)
command. Execute this command by specifying only the model and serialnum parameters, and
LDEV for the subtarget parameter. In the execution result of this command, the devNum value of
an LDEV appears under An instance of LDEV. Use this devNum value to specify the devnums
parameter.
poolid: Obtain this value from the execution result of the GetStorageArray (subtarget=Pool)
command. In the execution result of this command, the poolID value appears under An instance
of Pool. Use this value to specify the poolid parameter.
Device Manager CLI command reference188