HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

domainID=0
scsiID=15
lun=2
devNum=2
displayDevNum=00:02
osScsiBus=0
osScsiID=15
osLun=1
portWWN=11.22.33.44.55.66.77.88
fileSystemType=NTFS
fileSystemName=C:
sizeInMB=10
percentUsed=10
lastUpdated=1039003476
*****: The value is encoded by the CLI.
AddHostRefresh
AddHostRefresh refreshes the information about the hosts that Device Manager manages, which
is obtained from the Device Manager agent.
NOTE:
This command does not support virtualization servers. To refresh the information of a virtualization
server, use the RefreshVirtualizationServer command.
If the copy pair management host is unable to recognize a copy pair that was created on a host
that is not the copy pair management host, the copy status of that copy pair cannot be refreshed
even if the AddHostRefresh command is executed. In such a case, use the AddStorageArray
command to refresh the storage system containing the copy pair whose status you want to update.
Format
When refreshing the information for a host:
hdvmcli [URL] AddHostRefresh [options]
{objectid=object-ID-of-target-host|hostname=name-of-target-host}
Parameters
Table 80 AddHostRefresh command parameters
DescriptionStatusParameter name
Object ID of the target host
You must specify either objectid or hostname. Do not specify
both parameters at the same time. If they are specified at the
same time, an error will occur.
Optional
objectid
CLI Reference Guide 217