HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)

svolhostid=host-ID [svolinstancenum=instance-number] svolportnum=port-number
pvolarraytype=model pvolserialnum=serial-number pvoldevnum=device-number
[pvolportid=port-number|pvolportname=port-name]] pvolpoolid=pool-ID
svolarraytype=model svolserialnum=serial-number svoldevnum=device-number
[svolportid=port-number|svolportname=port-name]] pvolpoolid=pool-ID
[replicationfunction={BusinessCopy|ContinuousAccessSync|ContinuousAccessAsync
|Snapshot|ContinuousAccessJournal}] [munum=Mu-number] [fencelevel=fence-level]
[copytracksize=copy-pace] [pairoption=suspend]
Parameters
Table 98 AddReplication command parameters
DescriptionStatusParameter name
Copy group number
If you are using method 1, you must specify this parameter.
If you are using method 2 or 3, do not specify this parameter. If
you specify this parameter, method 1 is applied.
Optional
replication-
groupid
Group name used in the RAID Manager
Use a maximum of 31 bytes for a group name. The group name
cannot begin with a hash mark (#) or a hyphen (-).
If the replicationgroupid parameter is specified, this
parameter is ignored.
Optional
groupname
ID of the host that recognizes the primary volume (P-VOL)
If you are using method 2 or 3, you must specify this parameter.
If the replicationgroupid parameter is specified, this
parameter is ignored.
Optional
pvolhostid
Number of the HORCM instance that manages the P-VOL
If you are using method 2, you must specify this parameter.
If the replicationgroupid parameter is specified, this
parameter is ignored.
Optional
pvolinstan-
cenum
Port number of the HORCM instance that manages the P-VOL
Depending on the host OS, specify the appropriate value:
For Solaris systems: Specify an integer in the range 0-65535.
For AIX, Windows, HP-UX, or Linux systems: Specify an integer
in the range 1-65535.
If you are using method 3, you must specify this parameter.
If the replicationgroupid or pvolinstancenum parameter
is specified, this parameter is ignored.
Optional
pvolportnum
ID of the host that recognizes the secondary volume (S-VOL)
If you are using method 2 or 3, you must specify this parameter.
If the replicationgroupid parameter is specified, this
parameter is ignored.
Optional
svolhostid
Device Manager CLI command reference262