HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1 CLI Reference Guide (TB581-96051, May 2011)
• “GetStorageArray (subtarget=FreeSpace) ” on page 122
Table 113 FreeSpace instance attributes
DescriptionAttribute
Object ID of a region of unused capacity in the parity group
objectID
Size of a region of unused capacity in the parity group (in KB)
sizeInKB
Number of cylinders in a region of unused capacity in the parity group
0 is output for open volumes.
cylinders
Index number of a region of unused capacity in the parity group
Indexes are automatically reassigned whenever regions of unused capacity are
affected by the creation and deletion of LDEVs.
fsControlIndex
Host instance
The Host instance is output when the following commands are executed:
• “AddHost” on page 213
• “AddHostRefresh” on page 217
• “AddVirtualizationServer” on page 218
• “GetHost” on page 223
• “GetLogicalGroup” on page 197
• “MergeHost” on page 235
• “ModifyHost” on page 236
• “ModifyVirtualizationServer” on page 241
• “RefreshVirtualizationServer” on page 243
Table 114 Host instance attributes
DescriptionAttribute
Object ID of the host
objectID
Host name
If EXSP_xxxx_xxxx_xxxx is output as this value, the value indicates an
XP12000/XP10000/SVS200 port connected to an external storage system.
name
ID of the host
hostID
IPv4 IP address of the host
ipAddress
IPv6 IP address of the host
ipv6Address
Size of the LDEV allocated to the host (in KB)
For mainframe hosts, the value output for this attribute is 0.
capacityInKB
Device Manager CLI command reference290