HP XP7 Command View Advanced Edition Mainframe Agent Installation and Configuration Guide (TK981-96005, May 2014)

This specifies the device numbers for the range over which primary volumes for PPRC copy pairs
are scanned. For device-number-1, specify the initial DEVN of the scan range, and for device-
number-2, specify the last DEVN. For example, to scan primary volumes of PPRC copy pairs in
the device number range from 7000 to 7300, specify DEVN(7000,7300).
If device-number-1 is larger than device-number-2, device-number-2 is used as the
initial DEVN in the scan range, and device-number-1 is used as the last DEVN.
When the YKP2A command is executed, non-PPRC copy pairs are also detected. If both PPRC
copy pairs and non-PPRC copy pairs exist in the same environment, specify different values for
the following items so that each copy pair type is not detected at the same time.
Range of device numbers for scanned primary volume
Configuration file prefix
DAD(DADID1{,DADID2,[DADID3]}|{,,DADID3}) ~ <DAD string consisting of 1 to 28 characters>
DAD is a collection of volumes that can be accessed from the host. XP7 mainframe agent recog-
nizes which volumes that can be accessed by the device address domain ID. To generate config-
uration files for PPRC copy groups, specify different device address domain IDs for primary
volumes and secondary volumes.
Specify the following values for DADID1, DADID2, and DADID3:
DADID1: Device address domain ID for the primary volumes of the PPRC synchronous/asyn-
chronous/inner-DKC asynchronous copy pairs being scanned
DADID2: Device address domain ID for the secondary volumes of the PPRC synchronous/asyn-
chronous copy pairs being scanned
DADID3: Device address domain ID for the secondary volumes of the PPRC inner-DKC asyn-
chronous copy pairs being scanned
If DADID3 is omitted, the configuration files for PPRC inner-DKC asynchronous copy groups
cannot be generated.
To generate only the configuration files for PPRC inner-DKC asynchronous copy groups, specify both
DADID1 and DADID3, but omit DADID2.
The following examples show the specification of DAD parameters:
To generate configuration files for PPRC synchronous and asynchronous copy groups:
DAD(DADID1,DADID2)
To generate configuration files for PPRC synchronous, asynchronous, and inner-DKC asynchronous
copy groups:
DAD(DADID1,DADID2,DADID3)
To generate configuration files for PPRC inner-DKC asynchronous copy groups:
DAD(DADID1,,DADID3)
NOTE:
For the PREFIX initialization parameter, specify the same value as the value specified for DADID1.
CGNAME1(synchronous-copy-group-name) ~ <Copy group name string consisting of 1 to 6
characters>
This specifies the synchronous copy group name. A copy group name string, which consists of
one or multiple parts concatenated using periods, can be specified.
The copy group name specified by this parameter is appended with a 2-digit sequential number
starting with 00, resulting in copy group names that have a maximum of 8 characters. For example,
Using XP7 mainframe agent62