Troubleshooting Guide
Control panel message Description Recommended action
Emulation to IDE, and select File > Save
Changes and Exit. Reenter Computer Setup
and select Security > Drivelock Security.
For each listed Drivelock-capable SATA
device, ensure Drivelock is Disabled. Lastly,
change Storage > Storage Options > SATA
Emulation back to RAID and select File >
Save Changes and Exit.
1801-Microcode Patch Error Processor is not supported by ROM BIOS. 1. Upgrade BIOS to proper version.
2. Change the processor.
2200-PMM Allocation Error during MEBx
Download
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the computer,
restore the original memory
configuration, and reboot the computer.
4. If the error persists, replace the system
board.
2201-MEBx Module did not checksum
correctly
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the computer.
4. If the error persists, replace the system
board.
2202-PMM Deallocation Error during MEBx
cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the computer.
4. If the error persists, replace the system
board.
2203-Setup error during MEBx execution MEBx selection or exit resulted in a setup
failure.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
Table A-1 Numeric Codes and Text Messages (continued)
ENWW POST Numeric Codes and Text Messages 55