Overview
Installation of a D2200sb requires the following steps:
1. Install and configure an HP BladeSystem c-Class enclosure.
2. Install any D2200sb options.
3. Install the D2200sb.
4. Install the partner server blade.
For definitions of the acronyms used in this document, see
"Acronyms and abbreviations" in the storage blade user guide.
Kit contents
When unpacking the HP StorageWorks D2200sb PCIe storage
blade, locate the following items:
HP StorageWorks D2200sb PCIe storage blade
Half-height blade shelf
Documentation kit
Installing an HP BladeSystem c-
Class enclosure
Before performing any procedures specific to the D2200sb, install
an HP BladeSystem c-Class enclosure.
The most current documentation for HP BladeSystem components is
available at the HP website
(http://www.hp.com/go/bladesystem/documentation
).
Documentation is also available in the following locations:
Documentation CD that ships with the enclosure
HP Business Support Center website
(http://www.hp.com/support)
HP Technical Documentation website (http://docs.hp.com)
Half-height device bay numbering
Installation guidelines
When installing the D2200sb, observe the following guidelines:
Install hard drives in the D2200sb before installing the
D2200sb in the enclosure.
Be sure that the partner server blade is powered down before
installing the D2200sb.
Onboard Administrator is used to configure the enclosure and the
D2200sb. To function with the D2200sb, Onboard Administrator
version 3.10 or later is required.
Additional guidelines for installation with a
half-height partner server blade
When installing the D2200sb with a half-height server blade,
observe the following additional guidelines:
Install the D2200sb in any device bay.
If the D2200sb is installed in an odd-numbered bay, install the
partner server blade in the adjacent even-numbered bay to the
right.
If the D2200sb is installed in an even-numbered bay, install the
partner server blade in the adjacent odd-numbered bay to the
left.
Additional guidelines for installation with a
full-height partner server blade
When installing the D2200sb with a full-height server blade, observe
the following additional guidelines:
Remove the device bay shelf.
Install a PCI-Express mezzanine card into the server. For server-
specific information, see the D2200sb QuickSpecs.
Install the half-height blade shelf on the D2200sb.
Install the D2200sb in any device bay on the lower row of the
enclosure (9 through 16).
If installing two D2200sb storage blades with one partner
server blade, install the second D2200sb in the bay directly
above the first one.
If installing two D2200sb storage blades with one partner
server blade in an HP BladeSystem c3000 enclosure, use the
mini divider instead of the half-height blade shelf. For more
information, see the HP BladeSystem c3000 Enclosure Quick
Setup Instructions.
If the D2200sb is installed in an odd-numbered bay, install the
partner server blade in the adjacent even-numbered bay to the
right.
If the D2200sb is installed in an even-numbered bay, install the
partner server blade in the adjacent odd-numbered bay to the
left.
When installing the D2200sb with a full-height server blade, a
half-height server blade can be installed in the empty bay
above the D2200sb. This server blade cannot be partnered
with the D2200sb.
Installing a storage blade
CAUTION: To prevent improper cooling and thermal
damage, do not operate the D2200sb or the enclosure
unless all device bays and the first three hard drive
bays are populated with either a component or a
blank.
CAUTION: Thermal regulation is maintained only when
the hard drive drawer is closed. The hard drive
temperature alarm is triggered under the following
conditions:
A slow beep and flash (1 every 5 seconds) indicate
that the hard drive drawer is open. The hard drives
are not fully protected by system air flow.
A fast beep and flash (2 per second)To avoid
hard drive damage or data loss and storage blade
shutdown, close the hard drive drawer immediately.
When the hard drives reach critical temperatures, the
system shuts down.
1. Open the hard drive drawer.
2. Remove the blank, if necessary.
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The
only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Part Number 611259-001
September 2010 (First Edition)
Printed in the United States
*611259-001*
611259-001

Summary of content (2 pages)