HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes

4. Log in to the SMU and, from the Configuration View panel, right-click the system and select Tools
> Update Firmware.
A table displays currently installed firmware versions.
5. Click Browse, navigate to the temporary directory containing the downloaded firmware file, and
select the firmware file to install.
6. Click Install Controller-Module Firmware File. It takes approximately 10 minutes for the firmware
to load and for the automatic restart to complete on the controller to which you are connected.
Wait for the progress messages to specify that the update has completed. If Partner Firmware
Update is enabled, allow an additional 20 minutes for the partner controller to be updated.
7. In the SMU display, verify that the proper firmware version is displayed for each module.
Installing firmware using FTP
1. Save the downloaded firmware package in a temporary directory.
2. If you are using a Smart Component, extract the contents of the Smart Component using one of
the following methods:
In Windows environments, click Extract on the first screen of the Smart Component.
In Linux environments, enter ./CPxxxxxx.scexe --unpack=<folder name>
nl
(Where CPxxxxxx.scexe represents the downloaded firmware file.)
3. Prepare to use FTP:
a. Determine the network-port IP addresses of the system controllers.
b. Verify that the system FTP service is enabled.
c. Verify that the user you will log in as has permission to use the FTP interface and has manage
access rights.
d. Obtain the I/O module addresses to be loaded in the format channel-ID>:<EMP-number
(for example 0:15 or 1:31).
TIP: For a D2700 connected to a P2000 G3 array controller enclosure, the EMP addresses
are displayed in the SMU by clicking each enclosure in the Configuration View. The needed
data is displayed in the fields labeled EMP A Bus ID, EMP B Bus ID, EMP A Target ID, EMP B
Target ID, EMP A Revision, and EMP B Revision. (The terms bus and channel are equivalent.)
To obtain the EMP addresses using the CLI, enter the show enclosures command. The
needed data is displayed in the columns labeled EMP A CH:ID Rev and EMP B CH:ID
Rev.
There are typically two I/O modules in each drive enclosure.
4. Open a command prompt (Windows) or a terminal window (UNIX), navigate to the temporary
directory containing the firmware file to load, and install the firmware as follows:
a. Enter ftp <controller-network-address>
b. Log in as an FTP user.
In P2000 environments: user = ftp password = !ftp
In MSA2000 environments: user = ftp password = flash
c. Install the firmware by entering:
put <firmware-file> encl:<channel-ID>:<EMP-number> flash
nl
(Where firmware-file represents the downloaded firmware file.)
5. If needed, repeat these steps to load the firmware on additional modules.
6. Quit the FTP session.
7. In the SMU display, verify that the proper firmware version is displayed for each module.
8 Installation instructions