# hardware show storage status
Storage Set Status
--------–—--- ----––
Set 1 Formatted 34,876.99GB, Adding 37,134.57GB...
#
# system show status
Storage Set Status
--------–—--- ----––
Set Formatted 34,876.99GB, Adding 37,134.57GB...
Service Sets Status Notes
------------ ------ -----
Set 1 Running
#
7. Once the storage is available, performance will return to normal as long as parity initialization
was allowed to complete before the hardware add storage command was run.
Troubleshooting
Discover storage fails
The hardware discover storage command will fail if:
A previous discover storage command is already running.
There is no storage to be added.
There are insufficient expansion licenses applied to allow the entire expansion to complete
(in this case, no expansion will take place until sufficient licenses are present for all added
storage).
The storage is installed in the wrong disk bay locations for this expansion set.
There are any failed or predictive fail disks in either the existing or newly added storage.
The SAS cabling to the disk enclosures is incorrect.
There are any “foreign LUNs already present on the attached storage.
Add storage fails
The hardware add storage command will fail if:
There is an outstanding discover or add command in progress.
Any of the error conditions described above for the hardware discover storage
command have not been rectified.
Completing the RAID expansion 23