HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ022-90995, November 2013)

Figure 6 Template 1 cabling to customer's networks
bonded 10 GbE ports, normally to customer's data sub-net1 and 2
bonded 1 GbE ports, normally to customer's management sub-net3 and 4
See Factory default cabling (page 12). These should not be disconnected.light blue cables
Template 2, uses 1GbE network only
Template 2 supports users who have a 1GbE network only. The same network is used for data
and management.
The default bonding mode for this template is Mode 6.
The recommended IP address range is 17 in total: 1 for management and 16 contiguous for data.
NOTE: For software revision 3.3.0 and greater: customers who do not have a sufficient number
of physical Ethernet ports to support Template 2 should use Template 5 instead. See Number of
physical ports for each template (page 21).
Figure 7 Template 2 cabling to customer's networks
bonded 1 GbE ports to customer's data and management network1, 2, 3 and 4
See Factory default cabling (page 12). These should not be disconnected.light blue cables
Template 3, uses 10GbE network only
Template 3 supports users who have a 10GbE network only. The same network is used for data
and management.
The default bonding mode for this template is Mode 1.
The recommended IP address range is 17 in total: 1 for management and 16 contiguous for data.
NOTE: When using a 10GbE network, you must provide the correct SFPs for your environment.
They are not supplied with the product.
Supported network configurations (templates) 17