HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ022-90995, November 2013)

Figure 10 Template 5 cabling to customer's networks
bonded 1 GbE ports to customer's data and management network1 and 3
not used2 and 4
See Factory default cabling (page 12). These should not be disconnected.light blue cables
Recommended versus required IP addresses
As long as sufficient IP addresses are allocated during the network configuration process, the
B6000 Backup System will automatically assign IP addresses for all the nodes in the system when
the network is initially configured and, subsequently, when additional couplets are added.
If sufficient IP addresses are not allocated, the automatic IP address assignment process cannot be
performed. When additional couplets are added, it will be necessary to redo the network
configuration process and allocate a range sufficient for all IPs required by the system. Any IP
addresses that have been assigned to the nodes during the previous configuration will not be
preserved. Even if you enter the same physical IP addresses, the Virtual Data IP addresses will
change and you will need to reconfigure backup targets and replication. (You will not lose any
data.)
The following table summarizes the combined physical (P) and virtual (V) IP address requirements
for all possible couplet configurations. Ideally, you should always assign enough IP addresses to
cater for expansion, namely the values in the 4 couplet column.
Table 10 Recommended versus required IP addresses, P (physical, V (virtual)
3 couplets2 couplets1 couplet
4 couplets,
RecommendedTemplate
7 Mgt, 6P+1V
nl
5 Mgt, 4P+1V
nl
3 Mgt, 2P+1V
nl
9 Mgt, 8P+1V
nl
Template 1, two
sub-nets (1 GbE Mgt,
10GbE Data)
12 Data, 6P + 6V8 Data (4P + 4V)4 Data (2P + 2V)
16 Data, 8P + 8V
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
Template 2, single
network (1 GbE Mgt
and Data)
12 Data (6P + 6V)8 Data (4P + 4V)4 Data (2P + 2V)
16 Data (8P + 8V)
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
Template 3, single
network (10 GbE Mgt
and Data)
12 Data (6P + 6V)8 Data (4P + 4V)4 Data (2P + 2V)
16 Data (8P + 8V)
7 Mgt, 6P+1V
nl
5 Mgt, 4P+1V
nl
3 Mgt, 2P+1V
nl
9 Mgt, 8P+1V
nl
Template 4, two
sub-nets (1 GbE Mgt,
1GbE Data)
12 Data, 6P + 6V8 Data (4P + 4V)4 Data (2P + 2V)
16 Data, 8P + 8V
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
1 Mgt (1V)
nl
Template 5, single
network using two
12 Data (6P + 6V)8 Data (4P + 4V)4 Data (2P + 2V)
16 Data (8P + 8V)
1GbE ports only (1
GbE Mgt and Data)
Recommended versus required IP addresses 19