Brocade Web Tools Administrator's Guide v6.2.0 (53-1001194-01, April 2009)

84 Web Tools Administrator’s Guide
53-1001194-01
Configuring FC ports
5
FIGURE 43 Port Administration window, Table view
Configuring FC ports
With the FC Port Configuration wizard, you can configure allowed port types, port speed, and long
distance mode for physical ports.
You must use Web Tools with the EGM license enabled on the switch to configure long distance;
otherwise, access to this feature is denied and the following error message displays.
FIGURE 44 Missing EGM license
The EGM license is required only for 8 Gbps platforms, such as the Brocade DCX and DCX-4S
enterprise-class platforms, the Encryption Switch, the 300, 5300, and 5100 switches. For non-8
Gbps platforms, all functionalities are available without EGM license.