Displaying switch information
10
The Fan No. column indicates either the fan number or the fan FRU number, depending on the
switch model. A fan FRU can contain one or more fans.
For Brocade 4100, 4900, 5000, 5100, 5300, 7600, the 7500 and 7500E Extension
switches, and the Brocade Encryption Switch, the Fan No. column indicates the fan FRU
number.
The Brocade 200E, 300, 4012, 4016, 4018, 4020, and 4024 switches do not contain fan
FRUs, so for these switch models, the Fan No. column indicates the fan number.
NOTE
For these switches, if the Fan Status window has no “Fan Speed” column, the speed is not
monitored.
1. Select a switch from the Fabric Tree.
The selected switch appears in the Switch View. The icon on the Fan button indicates the
overall status of the fan.
2. Click Fan.
The detailed fan status for the switch is displayed, as shown in Figure 72.
Viewing the temperature status
The icon on the Temp button indicates the overall status of the temperature. For more information
regarding switch temperature, refer to the appropriate hardware documentation.
1. Select a switch from the Fabric Tree.
The selected switch appears in the Switch View. The icon on the Temp button indicates the
overall status of the temperature.
2. Click Temp on the Switch View.
The detailed temperature sensor states for the switch are displayed, as shown in Figure 73.
FIGURE 73 Temperature Sensor States window
Viewing the power supply status
The icon on the Power button indicates the overall status of the power supply status. For more
information regarding switch power modules, refer to the appropriate hardware documentation.