Brocade Web Tools Administrator's Guide v6.2.0 (53-1001194-01, April 2009)

180 Web Tools Administrator’s Guide
53-1001194-01
Fabric Watch threshold configuration
13
FIGURE 89 Threshold configuration in Fabric Watch
3. Click the Trait Configuration subtab.
4. In Fabric Watch Explorer, click a class.
5. Under Area Selection, choose an area from the list.
This sets the units in the Units field.
The module displays two columns of trait information, labeled System Default and Custom
Defined. You cannot modify the information in the System Default column.
6. In the Activate Level area:
Use the system default settings and proceed to step 11.
or
Click Custom Defined to specify new settings and proceed to the next step.
7. If necessary, select a time to record the event in the Time Base field.
8. Type the lowest boundary of the normal zone in the Low Boundary field.
9. Type the highest boundary of the normal zone in the High Boundary field.
10. Type the size of the buffer zone in the Buffer Size field.
11. Click Apply.