HP StorageWorks Fabric OS 6.0.1a release notes (AA-RWFMA-TE, June 2008)
Topic Description
IPSec for FR4-18i blade
and 400 Multi-protocol
Router
• IPSec implementation details:
• Pre-shared key
• Main m ode (IKE negotiation protocol)
• Tunnel mode in Encapsulating Security Payload (ESP)
• IPSec specificstatisticsnotprovided
• No NAT or IPv6 support
• Jumbo fram es will not be supported on secure tunnels.
• Internet Control Message Protocol (ICMP) redirect is not supported for
IPSec-enabled tunnels.
• Only a single secure tunnel will be allowed on a port. Non-secure tunnels will
not be a llowed on the same port as secure tunnels.
• Modify operations are not allowed on secure tunnels. To change the
configuration of a secure tunnel, you must first delete the tunnel and then
recreate it with the desired options.
• Onlyasinglerouteissupportedonaninterfacewithasecuretunnel.
• An IPSec tunnel cannot be created using the same local IP address if ipperf
is active and using the same local IP address (source IP address).
• Unidirectional supported throughput is approximately 104Mbytes/sec and
bidirectional supported throughput is approximately 90Mbytes/sec.
• An IPSec tunnel takes longer to come online than a non-IPSec tunnel.
• Fabric OS 6.x does not support IPSec with VLAN tagging.
• VLAN tagging support and IPSec support are mutually exclusive on a
per-tunnel basis.
IPv6 FCIP Tunnels
• Fab
ric OS 6.x does not support compression for IPv6 FCIP Tunnels
• Fab
ric OS 6.x does not support IPSec for IPv6 tunnels.
Distance mode
Distance setting is not persistent. After a configuration upload s and downloads,
distance settings will be lost, and the desired distance will be shown as 0.
Fibre Channel Routing
(FCR) switch
• If a Multi-protocol (MP) Router is present in the backbone fabric, the command
fosconfig - disable fcr maytakeupto8minutestocomplete. If
the MP Router is replaced by a FR4-18i or 400 Multi-protocol Router, the
command completes immediately.
• EX_Port trunking is not enabled by default.
• FCR switch does not support an edge fabric with one McDATA switch set to
never principal. The EX_Port connected to that edge fabric will not come up.
• FCR switch does not support edge fabrics that consist of McDATA switches
with domain ID offset. The EX_Port connected to that edge fabric may fail the
RDIprocessandnotcomeup. EX_Portscomeupdisabled(failtoinitializein
time) if attached to a Native mode switch running EOS 9.x that has non-default
DID offset configured.
Diagnostics
• All offlin e diagnostics commands should be used only when the switch is
disabled.
• POST can fail if new SFPs are added during POST. SFPs should only be added
while the switch is “online” or if the switch is powered off.
• When you use the diagnostic command s systemVerification and
diagSetBurnin, the switch or blade will fault when the burn-in error log
is full. Clear the burn-in log before running systemVerification or
diagSetBurnin.
• If there are ISLs present on the switch that are not used for routing (due to them
having higher linkcosts) , disable the links before running spinfab.
High Availability (HA)
If there is an already segmented port and backbone d evices are exported to
an edge fabric, a build fabric / fabric reconfiguration can occur after running
haFailover. Ensure that there are no segmented ports before upgrading
firmware.
HP StorageWorks Fabric OS 6.0.1a release notes