Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 3-9
Publication Number: 53-1000242-01
BL-1021
3
BL-1021
Message
Probable
Cause
Indicates that the switch had internal ports not online and that the system is retrying to bring the ports
that failed back online.
Recommended
Action
No action is required.
Severity INFO
BL-1022
Message
Probable
Cause
Indicates that the switch initiation failed because one or more of the internal ports was not online. The
switch is faulted.
Recommended
Action
Reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
Additional fault messages precede and follow this error, providing more information. See other error
messages for recommended action.
If the message persists, replace the switch.
Severity CRITICAL
BL-1023
Message
Probable
Cause
Indicates that the blade was reset before the initialization completed.
<timestamp>, [BL-1021], <sequence-number>,, INFO, <system-name>,
Retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>
<timestamp>, [BL-1022], <sequence-number>,, CRITICAL, <system-
name>, Init Failed: Switch DISABLED because internal ports were not
ONLINE, <list of internal port number not ONLINE>
<timestamp>, [BL-1023], <sequence-number>,, CRITICAL, <system-
name>, Blade in slot <slot number> was reset before blade init
completed. As a result the blade is faulted.