Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

3-10 Fabric OS Message Reference
Publication Number: 53-1000242-01
BL-1024
3
Recommended
Action
Reboot or power cycle the blade.
If the message persists, replace the blade.
Severity CRITICAL
BL-1024
Message
Probable
Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1025
Message
Probable
Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all GigE/FCIP data elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1026
Message
Probable
Cause
Indicates that an internal port went offline during the warm recovery of the switch.The switch will
reboot and start a cold recovery.
<timestamp>, [BL-1024], <sequence-number>,, INFO, <system-name>,
All ports on the blade in slot <slot number> will be reset as part
of the firmware upgrade.
<timestamp>, [BL-1025], <sequence-number>,, INFO, <system-name>,
All GigE/FCIP ports on the blade in slot <slot number> will be reset
as part of the firmware upgrade.
<timestamp>, [BL-1026], <sequence-number>,, CRITICAL, <system-
name>, Internal port offline during warm recovery, state <port
state> (0x<port ID>)