Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 5-5
Publication Number: 53-1000242-01
BM-1056
5
Severity WAR NIN G
BM-1056
Message
Probable
Cause
The policy of the specified switch is to persistently disable all ports the first time the AP is detected, and
either the:
AP was detected for the first time on this switch
Switch was configured under a different mode
Recommended
Action
Configure the switch and persistently enable the ports.
Severity INFO
BM-1058
Message
Probable
Cause
The automatic firmware upgrade on the AP has failed because AP firmware was detected to be different
from system firmware due to a firmware upgrade.
Recommended
Action
Issue the firmwareDownload command to recover the AP.
Severity WAR NIN G
<timestamp>, [BM-1056], <sequence-number>,, INFO, <system-name>, AP
is not configured. Persistently disabling all ports on the switch.
<timestamp>, [BM-1058], <sequence-number>,, WARNING, <system-name>,
Download of AP firmware failed for the switch. Reissue
firmwaredownload to recover.