Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 6-1
Publication Number: 53-1000242-01
Chapter
6
CDR System Messages
CDR-1001
Message
Probable
Cause
Indicates a deteriorated SFP, an incompatible SFP pair, a faulty cable between peer ports, or the port
speed configuration does not match the capability of the SFP.
Recommended
Action
Verify that you are using compatible SFPs on the peer ports.
Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace the
SFPs or cable if necessary. If there is a speed configuration mismatch, replace the SFP with a
compatible one or change the configuration.
Severity ERROR
CDR-1002
Message
Probable
Cause
Internal error. All the ports on the blade or switch will be disrupted.
Recommended
Action
For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover the
system. For a non-bladed system, perform fastBoot on the switch to recover the system.
Severity ERROR
<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>,
Port <port number> port fault. Please change the SFP or check cable
<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-
name>, Port <port number> chip faulted due to internal error.