Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 9-11
Publication Number: 53-1000242-01
EM-1037
9
EM-1037
Message
Probable
Cause
Indicates that the specified Power Supply has been marked as no longer being faulty. Probably because
its AC power supply has been turned on.
Recommended
Action
No action is required.
Severity INFO
EM-1041
Message
Probable
Cause
Indicates that sensors detected a warning condition. All significant sensors for the FRU are displayed;
each contains a header.
This message can display:
voltages in volts
temperature in Celsius
fan speeds in RPM
Recommended
Action
If the message is isolated, monitor the error messages on the switch. If the message is associated with
other messages, follow the recommended action for those messages.
Severity WAR NIN G
EM-1042
Message
Probable
Cause
Indicates that the indicated FRU has an incorrect number of sensors in its FRU header-derived
information. This could mean that the FRU header was corrupted or read incorrectly or corrupted in the
object database, which contains information about all FRUs.
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
<timestamp>, [EM-1037], <sequence-number>,, INFO, <system-name>,
<FRU Id> is no longer faulted.
<timestamp>, [EM-1041], <sequence-number>,, WARNING, <system-name>,
Sensor values for <FRU Id>: <Sensor Value> <Sensor Value> <Sensor
Value> <Sensor Value> <Sensor Value> <Sensor Value> <Sensor Value>
<timestamp>, [EM-1042], <sequence-number>,, WARNING, <system-name>,
Important FRU header data for <FRU Id> is not valid).