Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

9-18 Fabric OS Message Reference
Publication Number: 53-1000242-01
EM-2003
9
Severity CRITICAL
EM-2003
Message
Probable
Cause
Indicates that a FRU did not pass the Power On Self Tests. Please see the /tmp/post[1/2].slot#.log file
for more information on fault. The slot will be 0 for non-bladed systems.
Recommended
Action
On bladed systems, try reseating the specified FRU.
On nonbladed switches, reboot or power cycle the switch.
If the problem persists:
Run the systemVerification command to verify that the switch does not have hardware problems.
Refer to the Fabric OS Command Reference for more information on this command.
On bladed systems, replace the specified FRU, otherwise replace the switch
Severity ERROR
<timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>,
Slot <Slot Id> has failed the POST tests. FRU is being faulted.