Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-8 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1024
18
Recommended
Action
You might need to limit the number of port WWNs required by limiting the remote edge fabric
connectivity (which limits the number of translate domains). You can also limit the number of proxy
devices for a translate domain (which limits the number of translate domain ports required) by limiting
the devices specified in LSAN zones.
Severity WAR NIN G
FCR-1024
Message
Probable
Cause
Indicates that the number of devices in an LSAN defined in the edge fabric is greater than allowed by
the local LSAN zone database limitations.
Recommended
Action
Remove excess device entries from this LSAN zone until the number of devices is within the range of
the local LSAN zone database limitations.
Severity WAR NIN G
FCR-1025
Message
Probable
Cause
Indicates that the number of node WWNs detected to be in use is greater than the local node WWN
resources.
Recommended
Action
You might need to limit the number of node WWNs required by limiting the remote edge fabric
connectivity (which limits the number of translate domains).
Severity WAR NIN G
FCR-1026
Message
Probable
Cause
Indicates that the node WWN pool has rolled over and WWN entries detected to not be in use are reused
as needed.
<timestamp>, [FCR-1024], <sequence-number>,, WARNING, <system-
name>, Local LSAN zone <zone name> device entries for edge LSAN
exhausted.
<timestamp>, [FCR-1025], <sequence-number>,, WARNING, <system-
name>, Local phantom node WWN entries exhausted.
<timestamp>, [FCR-1026], <sequence-number>,, INFO, <system-name>,
Node WWN roll over.