Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

18-18 Fabric OS Message Reference
Publication Number: 53-1000242-01
FCR-1060
18
Probable
Cause
Indicates that the DH-CHAP authentication failed on the EX port.
Recommended
Action
Verify that the shared secrets on both sides of the link match.
Disable and enable the ports using the portDisable then portEnable commands to restart
authentication.
Severity INFO
FCR-1060
Message
Probable
Cause
Indicates that VC Link Init is enabled on the local switch and the remote switch is negotiating in
R_RDY mode. The fabric might not form properly.
Recommended
Action
Check the configuration on the local switch using the portCfgShow command to verify that the VC
Link Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY
mode.
VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that
uses R_RDY primitive for flow control.
Severity WAR NIN G
FCR-1061
Message
Probable
Cause
Indicates that a backbone fabric was built on the specified port.
Recommended
Action
No action is required.
Severity INFO
<timestamp>, [FCR-1060], <sequence-number>,, WARNING, <system-
name>, EX port(<port number>) has an incompatible configuration
setting.
<timestamp>, [FCR-1061], <sequence-number>,, INFO, <system-name>,
Backbone fabric created on port <port number>.