Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 18-19
Publication Number: 53-1000242-01
FCR-1062
18
FCR-1062
Message
Probable
Cause
Indicates that the maximum number of supported ports was exceeded. To enable this port, disable any
other operational port then re-enable the port.
Recommended
Action
No action is required.
Severity INFO
FCR-1063
Message
Probable
Cause
Indicates that the fabric ID of the switch does not match with the local switch.
Recommended
Action
Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends by
modifying either the local or remote host using the fcrConfigure command.
Severity INFO
FCR-1064
Message
Probable
Cause
Indicates that either the a backbone fabric split and both are connected to common edge fabrics, or the
fabric ID of two backbone fabrics, which are connected to an edge fabric, are the same.
Recommended
Action
If the backbone fabric split, merge the fabrics.
If two (or more) backbone fabrics have the same IDs, make the fabric IDs unique using fcrConfigure
command.
Severity ERROR
<timestamp>, [FCR-1062], <sequence-number>,, INFO, <system-name>,
Port <port number> disabled, system only supports <maximum ports>
ports.
<timestamp>, [FCR-1063], <sequence-number>,, INFO, <system-name>,
Fabric <fabric ID> for switch with domain ID: <domain ID> mismatches
with local fabric ID <local fabric ID>.
<timestamp>, [FCR-1064], <sequence-number>,, ERROR, <system-name>,
Fabric ID of backbone FC-Routers mismatch or overlap.