Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

23-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
FSS-1003
23
FSS-1003
Message
Probable
Cause
Indicates that the FSS has dropped the update because an application has not set the transaction flag
correctly.
Recommended
Action
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WAR NIN G
FSS-1004
Message
Probable
Cause
Indicates that the system ran out of memory.
Recommended
Action
Run the memShow command to view memory usage.
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
FSS-1005
Message
Probable
Cause
Indicates that the read system call to the FSS device failed.
<timestamp>, [FSS-1003], <sequence-number>,, WARNING, <system-
name>, Component (<component name>) misused the update transaction
(<transaction ID>) without marking the transaction beginning
<timestamp>, [FSS-1004], <sequence-number>,, ERROR, <system-name>,
Memory shortage
<timestamp>, [FSS-1005], <sequence-number>,, WARNING, <system-
name>, FSS read failure