Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 25-11
Publication Number: 53-1000242-01
FW-1049
25
Severity INFO
FW-1049
Message
Probable
Cause
Indicates that the value of the SFP voltage has changed. Frequent voltage fluctuations are an indication
that the SFP is deteriorating.
Recommended
Action
Replace the SFP if you see frequent voltage fluctuations.
Severity INFO
FW-1050
Message
Probable
Cause
Indicates that the value of the SFP voltage has fallen below the low boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity WAR NIN G
FW-1051
Message
Probable
Cause
Indicates that the value of the SFP voltage has risen above the high boundary. High voltages indicate
possible hardware failures. Frequent voltage fluctuations are an indication that the SFP is deteriorating.
Recommended
Action
If you see frequent voltage fluctuations, replace the SFP.
<timestamp>, [FW-1049], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1050], <sequence-number>,, WARNING, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1051], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.