Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

25-12 Fabric OS Message Reference
Publication Number: 53-1000242-01
FW-1052
25
Severity WAR NIN G
FW-1052
Message
Probable
Cause
Indicates that the value of the SFP voltage has changed from a value outside of the acceptable range to a
value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Severity INFO
FW-1113
Message
Probable
Cause
Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each time
you remove a cable or SFP. SFP failures also cause E_Ports to go down. E_Port downs might be caused
by transient errors.
Recommended
Action
Check both ends of the physical connection and verify that the SFPs and cables are functioning
properly.
Severity INFO
FW-1114
Message
Probable
Cause
Indicates that the number of times E_Ports have gone down has fallen below the low boundary. E_Ports
go down each time you remove a cable or SFP. SFP failures also cause E_Ports to go down. E_Port
downs might be caused by transient errors. A low number of E_Port failures means that the switch is
functioning normally.
<timestamp>, [FW-1052], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1113], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1114], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.