Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

25-66 Fabric OS Message Reference
Publication Number: 53-1000242-01
FW-1354
25
FW-1354
Message
Probable
Cause
Indicates that the number of invalid certificates has risen above the high boundary. This violation
indicates that a packet with an invalid certificate has been received from the primary FCS. Before a new
primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate
to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS
switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter
keeps track of the number of packets received with invalid certificates.
Recommended
Action
Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.
Severity WAR NIN G
FW-1355
Message
Probable
Cause
Indicates that the number of invalid certificates has changed from a value outside of the acceptable
range to a value within the acceptable range. This violation indicates that a packet with an invalid
certificate has been received from the primary FCS. Before a new primary FCS switch sends any
configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric.
The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed
by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets
received with invalid certificates.
Recommended
Action
No action is required.
Severity INFO
FW-1356
Message
<timestamp>, [FW-1354], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1355], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1356], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.