Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 25-79
Publication Number: 53-1000242-01
FW-1430
25
Probable
Cause
Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not
in the correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity WAR NIN G
FW-1430
Message
Probable
Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty
temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet command. A
temperature sensor is faulty when the sensor value is not in the acceptable range or is faulty.
Recommended
Action
Replace the FRU with the faulty temperature sensor.
Severity WAR NIN G
FW-1431
Message
Probable
Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty fans
is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when
sensor value is not in the acceptable range or is faulty.
Recommended
Action
Replace the faulty or deteriorating fan FRUs.
Severity WAR NIN G
FW-1432
Message
Probable
Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty
WWN cards is greater than or equal to the policy set by the switchStatusPolicySet command.
<timestamp>, [FW-1430], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Temperature sensor:
<Number Bad> bad.
<timestamp>, [FW-1431], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Fan: <Number Bad> bad.
<timestamp>, [FW-1432], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor WWN: <Number Bad> bad.