Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 28-3
Publication Number: 53-1000242-01
HIL-1106
28
For the SilkWorm 3900, replace the motherboard FRU.
For the SilkWorm 4100, if the 12 volt level is faulty, replace one or both power supplies; if any other
voltage is faulty, replace the entire switch.
Severity ERROR
HIL-1106
Message
Probable
Cause
Indicates that the switch voltage is below threshold. This message is specific to nonbladed switches and
is not applicable to the SilkWorm 12000, 24000, or 48000.
Recommended
Action
For the SilkWorm 200E, 3250 and 3850, the entire switch must be replaced, because these switches do
not have FRUs.
For the SilkWorm 3900, replace the motherboard FRU.
For the SilkWorm 4100, if the 12 volt level is faulty, replace one or both power supplies; if any other
voltage is faulty, replace the entire switch.
Severity ERROR
HIL-1107
Message
Probable
Cause
Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and
is not applicable to the SilkWorm 12000, 24000, or 48000.
Recommended
Action
For the SilkWorm 200E, 3250 and 3850, the entire switch must be replaced, because these switches do
not have FRUs.
For the SilkWorm 3900, replace the motherboard FRU.
For the SilkWorm 4100, if the 12 volt level is faulty, replace one or both power supplies; if any other
voltage is faulty, replace the entire switch.
Severity CRITICAL
<timestamp>, [HIL-1106], <sequence-number>,, ERROR, <system-name>,
Switch error, <nominal voltage> (<measured voltage>) below
threshold.
<timestamp>, [HIL-1107], <sequence-number>, FFDC, CRITICAL,
<system-name>, Switch faulted, <nominal voltage> (<measured
voltage>) above threshold. System preparing for reset.