Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

44-4 Fabric OS Message Reference
Publication Number: 53-1000242-01
MS-1021
44
Probable
Cause
MS failed while initializing the specified action.
The following actions might be displayed:
<while writing to ms_els_q>
MS is unable to write a message to the MS Extended Link Service Queue.
<while inserting timer to timer list>
MS is unable to add a timer to a resource.
Recommended
Action
This message is often transitory.
If the message persists, check the available memory on the switch using memShow.
Severity ERROR
MS-1021
Message
Probable
Cause
Indicates that the FSS warm recovery failed during WARM INIT phase of a reboot.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
MS-1022
Message
Probable
Cause
Indicates that Management Server Platform Service is being activated or deactivated.
Recommended
Action
No action is required.
Severity INFO
<timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>,
MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=<failure
reason>)
<timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>,
Management Server Platform Service <Activated or Deactivated>