Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

47-2 Fabric OS Message Reference
Publication Number: 53-1000242-01
PDM-1004
47
Probable
Cause
Indicates that a syntax error occurred when trying to launch the PDM process.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WAR NIN G
PDM-1004
Message
Probable
Cause
Indicates that the PDM process ran out of memory.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WAR NIN G
PDM-1005
Message
Probable
Cause
Indicates that the PDM failed to register to the FSS.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WAR NIN G
PDM-1006
Message
<timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-
name>, Memory shortage
<timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-
name>, FSS register failed
<timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-
name>, Too many files in sync.conf