Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 58-15
Publication Number: 53-1000242-01
SEC-1059
58
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
SEC-1059
Message
Probable
Cause
Indicates that the operation failed when writing to flash.
Recommended
Action
Run the saveCore command to FTP files from the switch and remove them from the flash.
Severity ERROR
SEC-1062
Message
Probable
Cause
Indicates either that no domains or domains more than the maximum number supported are specified.
Recommended
Action
Enter the correct number of domains.
Severity ERROR
SEC-1063
Message
<timestamp>, [SEC-1059], <sequence-number>,, ERROR, <system-name>,
Fail to <operation, e.g., save, delete, etc.,> <named item> to
flash.
<timestamp>, [SEC-1062], <sequence-number>,, ERROR, <system-name>,
Invalid number of Domains in Domain List.
<timestamp>, [SEC-1063], <sequence-number>,, ERROR, <system-name>,
Failed to reset statistics.