Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

58-18 Fabric OS Message Reference
Publication Number: 53-1000242-01
SEC-1074
58
SEC-1074
Message
Probable
Cause
Indicates that a security command was run on a switch that is not allowed to run it either because it is in
non-secure mode or because it does not have required FCS privilege.
Recommended
Action
If a security operation that is not allowed in non-secure mode is attempted, do not perform the operation
in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is,
either a backup FCS or primary FCS.
Severity ERROR
SEC-1075
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
SEC-1076
Message
Probable
Cause
Indicates that the NoNodeWWNZoning option has been changed. If the option is turned on, a zone
member can be added using node WWNs, but the member will not be able to communicate with others
nodes in the zone.
Recommended
Action
Reenable the current zone configuration for the change to take effect.
Severity ERROR
<timestamp>, [SEC-1074], <sequence-number>,, ERROR, <system-name>,
Cannot execute the command on this switch. Please check the secure
mode and FCS status.
<timestamp>, [SEC-1075], <sequence-number>,, ERROR, <system-name>,
Fail to <operation> new policy set on all switches.
<timestamp>, [SEC-1076], <sequence-number>,, ERROR, <system-name>,
NoNodeWWNZoning option has been changed.