Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 58-31
Publication Number: 53-1000242-01
SEC-1117
58
SEC-1117
Message
Probable
Cause
Indicates that the switch failed to save the data received by the primary FCS switch. This data can be an
FCS password, a non-FCS password, SNMP data, or multiple user authentication data.
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When all
switches are in the ready state, retry the operation.
Severity INFO
SEC-1118
Message
Probable
Cause
Indicates that the SNMP string could not be set.
Recommended
Action
Usually this problem is transient. Retry the command.
Severity INFO
SEC-1119
Message
Probable
Cause
Indicates that the secure Fabric OS was enabled by the secModeEnable command.
Recommended
Action
Verify that the security event was planned. If the security event was planned, there is no action required.
If the security event was not planned, take appropriate action as defined by your enterprise security
policy.
Severity INFO
<timestamp>, [SEC-1117], <sequence-number>,, INFO, <system-name>,
Fail to set <data>.
<timestamp>, [SEC-1118], <sequence-number>,, INFO, <system-name>,
Fail to set SNMP string.
<timestamp>, [SEC-1119], <sequence-number>,, INFO, <system-name>,
Secure mode has been enabled.