Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

58-40 Fabric OS Message Reference
Publication Number: 53-1000242-01
SEC-1164
58
Severity ERROR
SEC-1164
Message
Probable
Cause
Indicates that the attempt to enable security is made on a switch that is not present in the FCS list.
Recommended
Action
Add the switch into the FCS policy list when using the lockdown option to enable security.
Severity ERROR
SEC-1165
Message
Probable
Cause
Indicates that the system is low on memory.
Recommended
Action
Wait a few minutes and try the command again.
Severity ERROR
SEC-1166
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
<timestamp>, [SEC-1164], <sequence-number>,, ERROR, <system-name>,
Lockdown option cannot be applied on a non-FCS switch.
<timestamp>, [SEC-1165], <sequence-number>,, ERROR, <system-name>,
Low memory, failed to enable security on all switches.
<timestamp>, [SEC-1166], <sequence-number>,, ERROR, <system-name>,
Non FCS tries to commit failover.