Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 64-1
Publication Number: 53-1000242-01
Chapter
64
SYSM System Messages
SYSM-1001
Message
Probable
Cause
Indicates that the switch has run out of system memory.
Recommended
Action
Run the memShow command to view the switch memory usage.
Reboot or power cycle the switch.
Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity CRITICAL
SYSM-1002
Message
Probable
Cause
Indicates that a user has executed either the switchShutdown or switchReboot command. All services
are brought down for a logical switch.
Recommended
Action
No action is required if the switchShutdown or switchReboot command was executed intentionally. If
the switchShutdown command was run, you must run the switchStart command to restart traffic on
the logical switch.
Severity INFO
<timestamp>, [SYSM-1001], <sequence-number>, FFDC, CRITICAL,
<system-name>, No memory
<timestamp>, [SYSM-1002], <sequence-number>,, INFO, <system-name>,
<number>, Switch: <Switch number>